12/06/2022 Located condenser to roof. Removed condenser, opened lines at evaporator. Cut out old TXV, connected liquid line to distributor tube and soldered. Flushed out lines with Kleen Flush. Ran line set to condenser. Wired in a defrost clock and liquid line solenoid @ the condenser. Replace TXV and thermostat at evaporator. TXV equalizer line…
Read moreReplace Float Switch and Thermistor
12/05/2022 The float switch isn’t reading continuity after the 1-minute full cycle and the water sump is full. Procure parts and replaced float switch and thermistor. Timed 3 batches of ice. 28 minutes freeze time 3.5 minutes harvest time in Austin Texas. Near Barton Springs Austin, Texas 78704 Check out the Areas We Serve and…
Read moreWater Pump Outlet Hose was Kinked
On 12/03/2022 Problems found when taking apart water system; found water pump outlet hose was kinked causing a water restriction. Found water distributor plug disconnected causing a water system leak, repaired issues in Austin Texas. Near Brodie Lane Austin, Texas 78745 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/…
Read moreFound a Leak at the Suction Line Service Port
On 12/01/2022 Manager stated that freezer still short cycling and they turned it off. I turned it on and tested pressures. Found unit was low in gas in low weather conditions I added 1 lbs of 404 and started a leak search. Found a leak at the suction line service port. Tightened up the service…
Read more