On 01/30/2023 Found drain hub leaking under insulation and tape. Removed insulation and tape, replaced gasket and PVC drain adapter. Piping came lose from the PVC elbow Downstream of hub causing leak. Cleared drain line with nitrogen. Attached a quote to plum the entire drain line correctly in Austin Texas. Near Todd Lane Austin, Texas…
Read moreFound Loose Common Wire at Control Board in Air Handler
On 1/30/2023 Unit completely off upon arrival. Found loose common wire at control board in air handler. Connected. Monitored unit until thermostat satisfied. At one point the heat function was online while the thermostat was calling for cooling. This stopped when I reconnected common wire at air handler in Austin Texas. Near W 28TH1/2 ST…
Read moreReplaced the Bad Compressor with a New Compressor
On 1/26/2023 I arrived on site and began recovering the refrigerant from the system. After I recovered the refrigerant. I removed the filters in the liquid line and replaced the bad compressor with a new compressor installed new filter dryers on the liquid line. I pulled a vacuum on the system at that point I…
Read moreReplaced Warranty Drain Pan Heater and Drain Line Heater
On 1/23/2023 Replaced warranty drain pan heater and drain line heater. Watched box temp drop below 32*f in Georgetown Texas. Near Co Rd 245 Georgetown, Texas 78633 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3505]