On 12/29/2022 Ordered and picked up the compressor. Removed old compressor and cleaned condenser outside with water Installed new compressor with new start kit components, new c032s t-cap Then started flushing the lines, I have found that the cap tube was clogged. I had to uninstall it and use RX flush with nitrogen to clean…
Read moreRelocate the Condenser Unit Closer to the House in Designated Area
On 12/28/2022 Picked up the the warranty compressor at the warehouse. Proceeded to relocate the condenser unit closer to the house in designated area. Installed the line set under the house with hanger strap. Replaced compressor and dryer. Flushed system with nitrogen, made vacuum to 500 micron and added 6lbs of 410a. Installed disconnector with…
Read moreDead Lizard Touching the Fan Leg of the Capacitor
12/26/2022 On my arrival the tenant had the a/c turned off, he stated that the condenser was making loud noise in heater mode. Condenser it’s a heat pump, I have found that the fan motor it’s starting slow and noisy. Checked the electrical components and found a dead lizard touching the fan leg of the…
Read morePut Caps on to Fix The Leak
On 12/23/2022 I added 4 lbs of 407a to clear the sight glass, once cleared I started a leak search on the condenser. I have found that the liquid service port was leaking Freon they both suction and liquid didn’t have caps, I put caps on to fix the leak. Then placed all the coverts…
Read more