Defrost Timer Adjustments were Made

On 8/29/2023 WIC thermostat reading 44°F when arrived, evaporator coil restricted, had grease and debris, will need to move product to use chemicals to clean evaporator coil. Defrost timer adjustments were made for WIC/WIF, they were both behind an hour. Made adjustments to WIC defrost time, at 1am7am1pm7pm. Recommend evaporator be cleaned with chemical for WIC evaporator, and mount the door probe. (36•F read at thermostat upon departure) in San Marcos Texas.