Routine maintenance Cooling Refrigeration Repair

Routine Maintenance will help with recurring commercial refrigeration repairs. This self contained upright freezer wasn't getting to temp. The fans would not come on. With this as in other models the fans are activated by a klixon sensor that measures the temp of the coil. It holds off the fans until the coil is 5 degrees so as not to circulate warm air. The coils were not getting cold enough to turn on the fans which led to finding and fixing a refrigerant leak. Problem solved. Call us and we can help prevent reactive maintenance.