Cooler Defrost Clock was not working properly Causing the system not to turn on. I replaced the defrost clock and monitored to make sure it pulls down the temp and shuts off on 5/4/24 in Round Rock Texas. Near University Boulevard Round Rock, Texas 78665 Check out the Areas We Serve and jobs we are…
Read moreMoved Sensor to Return Air
Moved sensor to return air. Gaskets good seal 99% very small gap top corner of doors on center post. Condensation around doors is environmentally caused. Controller differential set at 8 degrees adjusted differential to 4 degrees and set fan for continuous on for off cycle defrost. Box pulling down to 33 degrees and cycling off…
Read moreFound Thermostat Wire Disconnected From Time Clock
Found thermostat wire disconnected from time clock. Reconnect wire. Solenoid opened. Unit on and cooling. Set thermostat to 35 on 5/1/24 in Austin Texas. Near San Jacinto Boulevard Austin, Texas 78701 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3505]
Read moreDeiced Coil and Unclogged the Drain
Deiced coil and unclogged the drain. I turned the system back and a watching it drop in temp on 4/30/24 in Round Rock Texas. Near S I-35 Frontage Rd Round Rock, Texas 78681 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3505]
Read more