Changed Condenser Fan Motor and Blade
On 3/15/2023 Added new suction tap to compressor. Changed condenser fan motor and blade. Replaced liquid line filter drier. Pulled a vacuum and charged system with 404a. Monitored system drop to temps bellow 20*f in Georgetown Texas.
Near West 2nd Street Georgetown, Texas 78626