Distribution tube clogged up bottom of pump heavily scaled up restricting water flow. Clean machine on 3/22/24 in Jarrell Texas. Near Town Center Blvd Jarrell, Texas 76537 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3505]
Read morePulled Top Off to Install New Plugs
Pulled top off to install new plugs, then started the ice machine cleaning. Cleaned the buildup off evaporator and out of water bin ran a cycle with sanitizer and due to the bin already being dirty due to the water leaking from the plugs previously popping off I cleared the first batch along with the…
Read moreReplaced Fan Cycle and High Pressure Switches
Replaced fan cycle and high pressure switches and drier. Pulled vacuum. Weighed nameplate charge in. Turned on unit on 3/19/24 in Round Rock Texas. Near W Industrial Blvd Round Rock, Texas 78681 Check out the Areas We Serve and jobs we are doing by clicking: https://prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3505]
Read moreCapacitor Wire Grounded to Fan Shroud
Capacitor wire grounded to fan shroud, repaired wire. Secure capacitor to unit base. Reset breaker. Unit came on started cooling. Unit base looks wet under discharge line. Leak check discharge line with bubbles. Not leaking on 3/18/24 in Austin Texas. Near Burnet Rd Austin, Texas 78757 Check out the Areas We Serve and jobs we…
Read more